Global Water WL430-034 Vented Wastewater Level Sensor, 0-34 ft Pressure Range, 40 ft Cable, 15 psi
- Brand: Global Water Instrumentations, Inc.
- Product Code: AP0200
- Availability: 10 - 14 Working Days
- Rp.33,600,000
Global Water's Sewage Lift Station Wastewater Level Sensor (WL430) is based on over 30 years of design and field service heritage.
The Sewage Lift Station Wastewater Level Sensor's "Steelcage" design offers the highest reliability in level measurement for severe high solids environments such as sewage, lift stations, storm canals, wet wells and slurry tanks. The waste water level transmitter system consists of a submersible pressure sensing element cased in a 316L SST housing. The lift station wastewater level sensor's electronics are capable of withstanding lightning strikes and meet RCTA/DO 160D for lightning direct effects and surge protection for FAA and MIL-STD test and NASA standard electrical surge requirements. All Sewage Lift Station Wastewater Level Sensors are corrosion resistant and clog free. The WL430 Sewage Lift Station Wastewater Level Sensor is supplied with 40 ft. of standard polyurethane shielded and vented cable. The lift station waste water level transmitter's unique cable venting system allows for barometric pressure differential compensation while keeping the elements out, using a Gortex filter encapsulated tip. The "Steelcage" design gives full protection and allows sensing to sewage levels no matter how much debris/mud/sand or rags build up.Includes:
- Global Water WL430-034 Vented Wastewater Level Sensor, 0-34 ft Pressure Range, 40 ft Cable, 15 psi
Specifications:
WL430 Wastewater Level Sensor Electrical
- Supply Voltage: 8 - 38 Vdc
- Output: 4-20 mA
- Zero Balance: ± 1% Full Scale Output (FSO)
- FSO Setting: ± 1% FSO
- Resolution: Infinite ( ±0.001% FSO usable)
- Response Time: < 5 mS
- Insulation Resistance: 1000 MO @ 50 Vdc
- Reverse Polarity: Protected
- Warm-Up: < 10 mS
- Power Supply Effect: = ± 0.002% FSO per V input
- EMI/RFI: Internal Filtering
- Lightning Protected: MOV and dual gas discharge tube
- Short Circuit Protected: Up to 40 Vdc
Wastewater Level Sensor Performance
-
Static Accuracy: ± 0.5% FSO ( BFSL, RSS) (combined effects of non-linearity, hysteresis
& repeatability)
- Repeatability: ± 0.1% FSO
-
Temperature Effects: ± 1.5% FSO over comp range (combined effects of Zero & FSO with
reference at 70°F)
- Long Term Stability: ± 0.25% FSO per year
Wastewater Level Sensor Mechanical
- Pressure Ranges: 10psi (23 ft) or 15psi (34 ft)
- Proof Pressure: 2x Full Scale
- Burst pressure: 5x Full Scale
- Materials: 316L SST plus cable
- Pressure Port: Flush mount per outline
- Electrical Connector: 1/2 inch-NPT Male submersible conduit fitting with 40ft of polyurethane cable
- Dimensions: 3 inch diameter x 6 inch long (7.6 cm dia. x 15 cm long)
- Weight: Nominal 20 oz (.57 kg)
- Compensated Temp Range: 20 to 170°F (-6 to 76°C)
- Operating Temp Range: 0 to 200°F (-17 to 93°C)
- Storage temp range: -20 to 250°F (-28 to 121°C)